Komatsu PC-EPC Solenoid Valve

Posted on:       View:5700

What is PC EPC Valve  Solenoid System


The PC-EPC valve mainly senses the actual speed of the engine and gives corresponding signals to adjust the pump flow.

As the operating conditions change, the engine speed will also change, and the pump flow rate that matches the engine should change accordingly. launch

The speed change of the engine is transmitted to the computer through a speed sensor installed on the engine flywheel housing, and then the computer sends a command for the change in pump flow, and the PC-EPC solenoid valve receives this command. Properly adjust the pump flow through the PC valve to correspond to changes in engine speed.

In addition, the current of PC-EPC is also related to factors such as to monitor instructions and main pump pressure.


working principle

The computer detects the actual speed of the engine through the speed sensor. When the load increases and the engine speed decreases, the computer will issue a command to the PC-EPC valve, so that the command current flowing to the PC-EPC solenoid valve increases according to the decrease in the engine speed. Large, to reduce the angle of the swash plate of the pump, reduce the output flow of the pump, and restore the engine speed.

9.jpg

Troubleshooting

Trouble phenomenon: the engine smokes when digging under heavy load, sometimes it will stall

Inspection result: Check that the coil resistance of the EPC solenoid valve is 0, and confirm that the solenoid internal coil is burned out.

During heavy-duty excavation, the PC-EPC command to reduce the pump flow sent by the computer cannot be received. Therefore, the PC valve cannot control the pump flow under heavy load. Excessive pump flow causes the pump horsepower to be greater than the engine horsepower, so black smoke is emitted

Troubleshooting: Better EPC solenoid valve machine transfer is normal

Test

Remove oil pressure measuring plug 5, install M10 quick-change connector and 5.9Mpa oil pressure gauge.

Test Conditions

1. Hydraulic oil temperature: 45℃-55℃

2. Working mode: A mode (PC-8 P mode)

Engine speedJoystickPC-EPC valve output pressure
Low idleneutral2.9Mpa
High idle0

1.png



Where is the EPC valve on the excavator

Open the pump outer cover, you can see the LS-EPC solenoid valve, its input oil pressure comes from the self-pressure reducing valve, the voltage signal comes from the computer board: the voltage signal from the computer is different, the position of the internal spool is different, and The output oil pressure is also different. This output oil pressure enters the LS valve. 

1.jpg2.jpg



Komatsu EPC valve figure


Komatsu PC-7 LS-EPC Solenoid Valve figure

Check it here https://excavator-part.com/blogs/detail/83 


Komatsu PC-200-6 EPC Solenoid Valve figure

3.jpg

Komatsu PC-300-7 EPC Solenoid Valve figure

4.jpg

How to change the  issue EPC valve

----LS-EPC Solenoid Valve


Symptom: In L mode, the driver reports that the micro-operation performance is not good.

 

Inspection result: The solenoid coil of the LS-EPC solenoid valve is hot.

 

Failure analysis: Because the coil is burned out, no electromagnetic force can be generated to promote the movement of the valve core, so the pilot pressure oil from the self-pressure reducing valve cannot enter the LS valve through the solenoid valve. As a result, the precise flow control of the pump is lost.

 

Troubleshooting: Micro operation performance becomes better after replacing LS-EPC solenoid valve











 ----PC-EPC Solenoid Valve


Failure phenomenon: When the engine is excavated under heavy load, it emits black smoke and sometimes stops.

 

Inspection result: The inspection result PC-EPC solenoid valve coil resistance is 0 (standard value is 7-140) to confirm that the internal coil of the solenoid valve is burned out.

 

Failure analysis: During heavy load excavation, the PC-EPC valve issued by the computer to reduce the pump flow cannot be received, so the PC valve cannot adjust the pump flow during heavy load. The engine emits black smoke and even stalls





 

Troubleshooting: Replace the PC-EPC solenoid valve and the machine runs normally

How buy aftermarket parts for epc valve for  excavators online

 

EPC Valve  Solenoid online dealer/sales near me Vietnam

If your area is Vietnam, and you want to know more or even to visit it, we will tell you the detailed address,you can contact:Tel/Whatsapp/WeChat: +86 138 2229 1434,Facebook: Nina Yangu.

 

EPC Valve  Solenoid online dealer/sales near me Cambodia

If your area is Cambodia, and you want to check if the goods you need are in stock, you could contact: Tel/Whatsapp/WeChat: +86 138 2229 1454, Facebook: Stephanie Yangu.

 

EPC Valve  Solenoid online dealer/sales near me South Africa

If your area is South Africa, and you have questions about excavator spare parts, you can contact: Tel/Whatsapp/WeChat: +86 138 2229 1434, Facebook: Nina Yangu.

 

EPC Valve  Solenoid online dealer/sales near me Manila

If your area is Manila, you can contact the Manila contact:

Tel/Whatsapp/WeChat: +86 138 2229 1454, Facebook: Stephanie Yangu.



1.jpg



If you need more Komatsu EPC Valve Solenoid other models, you can contact the wholesaler contact:Tel/Whatsapp/WeChat: +86 138 2229 1454, Facebook: Stephanie Yangu.

5.jpg

If you need more Kato EPC Valve Solenoid other models, you can contact the wholesaler contact: Tel/Whatsapp/WeChat: +86 138 2229 1434, Facebook: Nina Yangu.





6.jpg



If you need more Cat Valve Solenoid, other models, you can contact the wholesaler contact: Tel/Whatsapp/WeChat: +86 138 2229 1454, Facebook: Stephanie Yangu.


7.jpg

If you need more Hitachi Valve Solenoid other models, you can contact the wholesaler contact: Tel/Whatsapp/WeChat: +86 138 2229 1434, Facebook: Nina Yangu.


8.jpg

If you need more Kobelco Valve Solenoid other models, you can contact the wholesaler contact: Tel/Whatsapp/WeChat: +86 138 2229 1454, Facebook: Stephanie Yangu.