Merging valve and diverter valve operating principle

Posted on:       View:2236

                         Merging valve and diverter valve

Description
The function of the merging valve and diverter valve is to help the pump merge or split oil flows P1 and P2 to the control valve.At the same time, the LS control system is also merged or shunted.

Corresponding positional relationship

分流阀.jpg            分流阀1.jpg

Structure

分流阀2.jpg    9_20191219161120.jpg       分流阀4.jpg


Working principle

The pump controller issues a command of the merge/shunt based on the monitor's instructions and the status of the joystick. This command is executed by the merging valve and diverter valve to merge or split the front and rear pump pressure oil and LS system.


1、Merging valve and diverter solenoid valve is de-energized(Pilot pressure PS off)------- confluence


分流阀7.jpg

分流阀8.jpg



2、Merging and diverter solenoid valves energized(Pilot pressure PS on)---------Shunt

9_20191219162204.jpg




9_20191219162257.jpg